AdBlue / SCR service in Tbilisi

AdBlue OFF SCR system
software deactivation

AdBlue is the fluid used by the SCR (Selective Catalytic Reduction) system to reduce nitrogen oxides. In the event of a warning, reduced power or a starting problem, we use diagnostics to identify the cause and explain whether repairs are needed or software deactivation is possible.

How AdBlue works
Illustrated cutaway of an AdBlue system and SCR catalyst

Normal operation

Outlet NOx
44ppm
Dosing
100%

The injector sprays AdBlue into the exhaust stream. In the SCR catalyst, most NOx is converted into nitrogen and water vapour.

Readings and motion are illustrative.

How the system works

What is AdBlue and how does SCR work?

AdBlue (DEF) is an aqueous urea solution stored in a separate tank. The SCR system uses it to reduce nitrogen oxides (NOx) in diesel exhaust.

The pump supplies fluid to the injector, which sprays it upstream of the SCR catalyst. Ammonia forms in the hot exhaust; inside the catalyst, it reacts with NOx to produce nitrogen and water vapour.

Dosing begins when the system has warmed up sufficiently and the required conditions are met. The ECU controls the dose using temperature, load and sensor data. A fault may lead to a power restriction or prevent the engine from restarting, depending on the model and the cause.

Software changes

  • SCR/AdBlue control logic is disabled in the software
  • Fault codes related to this system are disabled
  • The SCR/AdBlue countdown, power limits and engine restart restrictions are removed
  • The deactivated system no longer requires AdBlue refills
  • Other SCR/AdBlue-related software parameters are changed according to the vehicle and ECU

Starting or power problems caused by other faults, and mechanical damage, require separate work. Nitrogen oxide (NOx) levels in the exhaust may increase after SCR deactivation.

Recognising the problem

What are the signs of a problem?

  • Starting and power restrictions

    A countdown of the remaining distance or a warning that the engine will not restart appears. The vehicle may enter limp mode and power may be restricted.

  • NOx sensor and dosing

    Diagnostics indicate a fault with the NOx sensor, AdBlue pump, pressure or fluid dosing. We identify the cause by checking system data and components.

  • Fluid quality and level

    The display shows an AdBlue quality or low-level warning. Sometimes the message remains even after refilling.

We determine the required work through diagnostics. If the system leaks or a physical obstruction prevents exhaust from flowing, mechanical work is needed alongside the software changes.

Stages

Four stages of the work

  1. Diagnostics and readingWe check SCR fault codes and live data. We read the software via OBD or by direct ECU access using the Bench or Boot method.
  2. Custom calibrationWe process the file for the specific vehicle, disabling SCR/AdBlue control logic and the relevant fault codes.
  3. Writing the softwareWe write the processed file to the ECU and verify that writing is complete.
  4. TestingWe check vehicle operation, live data and SCR/AdBlue-related faults.

Questions and answers

Frequently asked questions

Which vehicles do we work on?

Diesel passenger cars and trucks equipped with SCR/AdBlue, regardless of make. We determine whether software deactivation is possible based on the specific ECU and the condition of the system.

Will the AdBlue countdown disappear?

After software deactivation, the SCR/AdBlue-related countdown and engine restart restriction are removed. Problems caused by other faults require separate diagnostics.

Do you work on Euro 6 trucks?

Yes, we also work on Euro 6 trucks. We check the ECU, software version and system faults. We determine whether the work is possible after diagnosing the specific vehicle.

Is mechanical work also needed?

If the system leaks or a physical obstruction prevents exhaust from flowing, mechanical work is needed alongside the software changes. After diagnostics, we clarify what needs to be done.

Mercedes-Benz X253, 2017 · 2.2 L — DPF, EGR, AdBlue, Start/Stop software deactivation.

Work completed

Mercedes-Benz X253

2017 · 2.2 L

DPF, EGR, AdBlue, Start/Stop software deactivation.

View this project

Send us a photo of the warning

Provide the vehicle model, year and engine. Attach a photo of the display or a fault code. We will explain what checks are needed and how to proceed. The consultation is free.

Call WhatsApp